Operating Manual of G2.5
The G2.5 diaphragm meter is completely acquired by the standard of OIML R31:1995. Its high quality such as wide range of flow rate, high sensitivity, stable performance, good-looking appearance, high safety and long using periods makes it widely used in metrology region of gas, natural gas and liquid petroleum gas etc.
Main structure feature:
- Wide range of flow rate, high sensitivity and stable accuracy
- High intensity shell and anticorrosive coating
- New technique producing diaphragm makes accrual metrology performance possible
- Magnet kinematical transmission keep excellent sealing
- Screw tightening of upper case and lower case makes maintenance simple and convenient
- Electrostatic-plastics-powder-painting of upper and lower case form pure excellent appearance of meters with high burnish and anticorrosive ability
Main specific parameters:
|
Specification: G2.5
|
|
Items
|
Capacity performance
|
|
Qn (m³/h)
|
2.5
|
|
Qmax (m³/h)
|
4
|
|
Qmin (m³/h)
|
0.025
|
|
Basic Error
|
0.1Qmax≤Q≤Qmax
|
±1.5%
|
|
Qmin≤Q < 0.1Qmax
|
±3%
|
|
Working Pressure kPa
|
0.5~50
|
|
Pressure Loss Pa
|
≤50
|
|
Cycle volume dm³
|
1.2
|
|
Maximum Index m³
|
99999.999
|
|
Minimum Index dm³
|
0.2
|
|
Working Temperature ºC
|
-10 ~ +40ºC
|
|
Weight kg
|
2
|
|
Average Using Periods year
|
10
|
Notification:
Delivery and storage
- Please keep the meters upward and avoiding collision during delivery process. The meter should be stored in a drying location without corrosive medium and with a temperature among –20 ºC to 50 ºC.
Installation
- The installation position should be far from fire, moisture, violent vibration and direct sun shine.
- Please make gas piping system cleaning and seal before install the meter.
- Please verify the right connection direction, which is connector at the end of upper case arrow should be connected to gas supply pipe.
- Please install meter upward.
- The tighten torque put on screw connector should be less than 110 N·m,and the bending moment should be less than 40 N·m.
- A valve should be installed before inlet of meter in gas piping system.
Installation Dimensions
|
Spe.
|
Dimensions(mm)
|
|
A
|
B
|
C
|
D
|
E
|
F
|
|
G2.5
|
130
|
224
|
214
|
164
|
70
|
M30×2
|
Using:
- Please make sure the inlet gas pressure is less than the maximum working pressure.
- Don’t use fire to check meter’s leakage.